Continuous Particulate Monitor BAM 1020

Updated:2025-03-13

Views:3521

  • Brand:MetOne
  • Model:BAM 1020
  • Description: The BAM 1020 automatically measures and records airborne particulate concentration levels (in milligrams or micrograms per cubic meter) using the industry-proven principle of beta ray attenuation. Tho
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

BAM 1020 連續顆粒物監測儀概述:

user's manual

The BAM 1020 automatically measures and records airborne particulate concentration levels (in milligrams or micrograms per cubic meter) using the industry-proven principle of beta ray attenuation. Thousands of BAM 1020 units are currently deployed worldwide, making the unit one of the most successful air monitoring platforms in the world.

DESIGNATIONS:

Met One Instruments’ Model BAM 1020 was the first instrument to obtain U.S. EPA Federal Equivalent Method (FEM) designation for continuous PM2.5 monitoring, in addition to its longstanding EPA designation for PM10 monitoring. The BAM 1020 has also obtained the corresponding PM2.5 and PM10 certifications in the European Union. Two BAM 1020 units can also be operated together as an EPA designated PM10–2.5 coarse method. Met One Instruments supplies complete sampling accessory kits for compliance with each designation.

OPERATIONS / INTERFACE:

At the beginning of each sample hour, a small 14C (carbon-14) source emits a constant source of high-energy electrons (known as beta rays) through a spot of clean filter tape. These beta rays are detected and counted by a sensitive scintillation detector to determine a zero reading. The BAM 1020 then advances this spot of tape to the sample nozzle, where a vacuum pump pulls a measured and controlled amount of outside air through the filter tape, loading it with ambient dust. At the end of the sample hour, this dust spot is placed back between the beta source and the detector, thereby causing attenuation of the beta ray signal which is used to determine the mass of the particulate matter on the filter tape. This mass is used to calculate the volumetric concentration of particulate matter in ambient air.

DATA COLLECTION:

All data files are accessible via an industry standard duplex RS-232 serial port using common terminal programs or Met One Instruments’ software such as Air Plus® or Comet®. The data is available in a variety of formats including daily reports, last record, all data, and new records since last download. Configuration files, error logs, and flow statistics are also available. Ethernet and USB data collection are standard.

FEATURES:

  1. U.S. EPA Equivalent Method for PM10, PM2.5, and PM10-2.5 monitoring
  2. Long term unattended remote operation of up to 60 days between site visits
  3. Very low operating costs
  4. Automatic Span Calibration checks
  5. Fast and easy field audits using common FRM audit tools
  6. Bench top or equipment rack mounting in mobile or stationary shelters
  7. Rugged anodized aluminum, stainless steel, and baked enamel construction
  8. Highly accurate, reliable, and mechanically simple flow system
  9. Hourly filter advances minimize effects on volatile compounds
  10. Advanced Smart Heater technology precisely controls sample relative humidity
  11. Integrated datalogger allows the connection of up to two multi-parameter meteorological sensors
  12. Data retrieval through RS-232 or RS-485 serial ports using direct PC connections, or digital data collection systems
STANDARD EQUIPMENT:
  • Operation Manual and Quick Setup Guide
  • Internal Automatic Span Membrane
  • Internal Flow Sensor and Flow Controller
  • Internal Filter Temperature, Pressure, and Relative Humidity Sensors
  • Six Channel Data Logger for Accessory Sensors
  • Serial Data Cable and Modular Power Cable
  • Pump Control Cable and Air Tubing
  • Rack Mounting Brackets and Hardware
  • COMET® Data Collection Software
  • One Roll of 460180 Glass Fiber Filter Tape
COMPLETE SAMPLING ACCESSORY KITS:
  • FEM2.5 Accessory kit for EPA PM2.5 configuration
  • EU2.5 Accessory kit for EU PM2.5 configuration
  • PM2.5 Accessory kit for non-regulatory PM2.5
  • PM10 Accessory kit for EPA PM10 configuration
  • EU10 Accessory kit for EU PM10 configuration
  • COARSE Accessory kit for EPA PM10-2,5 dual-unit configuration
INDIVIDUAL SAMPLING ACCESSORIES AND OPTIONS:
  • BX-121 & BX-122 High Capacity Gast Pump
  • BX-126 & BX-127 Low Noise Medo Pump
  • BX-802 EPA Louvered PM10 Inlet
  • BX-808 BGI PM2.5 VSCCTM Cyclone
  • BX-807 BGI PM2.5 Sharp Cut Cyclone
  • BX-811 BGI PM 1 Sharp Cut Cyclone
  • BX-827 & BX-830 Smart Inlet Heater
  • BX-803 TSP Inlet with Debris Screen
  • BX-302 Zero Filter Audit Kit with Leak Valve
  • BX-305 Leak Check Valve with Hose Barb
  • BX-344 Inlet Cleaning Kit
  • BX-308 Service Tool Kits
  • BX-598 Digital Temperature Sensor
  • BX-597A Digital Temperature, Relative Humidity, Barometric Pressure Combination Sensor
  • BX-902B, BX-903, & BX-906 Weatherproof Mini Shelter
  • BX-801 Standard 8’ Inlet Tube Kit With Roof Flange
  • 8112-X Custom length inlet tubes, up to 8 feet per segment
  • Inlet tube extension kits, up to 16 feet total
  • Phone, cellular, radio, and satellite modem kits
Applications:
  • Ambient Monitoring
  • Environmental Monitoring
  • Climate Research

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@m.jidi9.com
主站蜘蛛池模板: 日本久久久久久久| 成人a在线观看| 国产精品美女久久| 99在线热播| 91精品国产自产91精品| 久久精品国亚洲| 色综合久久天天综线观看| 久久全国免费视频| 亚洲欧美国产不卡| 国产精品久久久久久亚洲影视| 久久波多野结衣| 日本免费一区二区三区视频观看| 亚洲中文字幕无码不卡电影| 国产精品国产三级国产aⅴ浪潮| 久久99精品久久久久久噜噜| 国产精品久久婷婷六月丁香| 国产日本欧美在线观看| 激情伊人五月天| 国产一区二区丝袜| 久久99视频免费| 美女在线免费视频| 日韩精品视频在线观看视频| 亚洲永久激情精品| 日韩免费在线播放| 欧美精品成人在线| 久久久91精品国产| 久久69精品久久久久久久电影好| 久久久久人妻精品一区三寸| 免费在线观看一区二区| 久久久久国产一区二区三区| 蜜桃视频成人在线观看| 久久成人av网站| 国产精品青草久久久久福利99| 国产精品久久久久高潮| 韩国视频理论视频久久| 国产又爽又黄的激情精品视频| 国产精品久久久久久久午夜| 国产精品日韩在线一区| 91高清免费视频| 日韩欧美精品在线不卡| 欧美精品久久久|