current position:home page>Products>Measuring Instrument>Hukseflux>

FTN02 Field thermal needle system

Updated:2025-03-13

Views:3016

  • Brand: Hukseflux
  • Model:FTN02
  • Description: FTN02 Field thermal needle system performs accurate on-site (field) measurements of the thermal resistivity and thermal conductivity of soils. Measurements with FTN02 comply with ASTM D5334 and IEEE 4
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

FTN02 Field thermal needle system: User's Manual Datasheet

Thermal Needle Measuring System

FTN02 is a thermal needle measuring system for on-site measurements of thermal conductivity (or the inverse value, resistivity) at depths from the surface down to a depth of 1.5 metre. Due to its robustness and length, FTN02 is the best solution for route-surveying of high-voltage electric power cables and heated pipelines (typical depth of burial of 1.5 m). The measurement method is based on the use of a “thermal needle”. This method employs a heating wire and a temperature sensor in a needle. The FTN02 system consists of the thermal needle, model TP09, mounted on a long lance, LN02, and a control and readout unit CRU02. FTN02 is easy to use. After making a small-diameter access hole, the thermal needle TP09 is brought down to just above the point that must be investigated and then pushed into the local undisturbed soil below. The user performs control and readout of the measurement from the handheld CRU02. The measurement result is generated immediately by the CRU02 from the analysis of the time series of the temperature and the heating power during the heating interval.

Advantages

Suitable for on-site (field) surveys: FTN02 is sufficiently robust to survive rough handling during a typical survey. It performs measurements as a stand-alone unit. The batteries in the CRU02 can be recharged through the cigarette-lighter receptacle in an automobile, using the CA02 car adapter, or from 220/110 VAC using the WSA02 wall socket adapter.

Saving time: With FTN02 there is no need for digging a large-diameter access hole to perform measurements. Because of the lance LN02, drilling a small access hole made with a ground drill, typically 30 mm in diameter, is sufficient. With measurement systems without a lance, such as MTN02, the user has to make a large-diameter access hole or even to dig a trench. A typical measurement requires around 60 s to get to thermal equilibrium plus 300 s for the actual heating interval.

Easy data processing: CRU02 gives an immediate indication of the end result and an indication of the quality of the measurement. It can store 50 measurements. ASTM and IEEE require that the end result is visually checked and recalculated. This is typically done during later analysis of the measured data in a spreadsheet. CRU02 is connected to a PC by using USB.

Local calibration / conformity assessment: The accuracy of the measuring system can be verified (before a survey) by measurement in glycerol. For high accuracy verification against a reference material with formal traceability, CRC05 calibration reference cylinders can be separately purchased.

Suggested Use

  • Route surveys, on-site (field) measurements
  • With extension for laboratory analysis of soil specimens (see TNS02)
  • Areas of Application

  • Geotechnics / soil thermal route analysis
  • Material characterisation / thermal conductivity measurement
  • FTN02 Field thermal needle system Specifications:

    Measurand Thermal conductivity, thermal resistivity
    Measurement range 0.1 to 6 W/(m?K) (all common soils)
    Rated operating temperature range from 0 to +50 °C
    Measurement method absolute measurement per ASTM D 5334-08 and IEEE Standard 442-1981(03)
    Data analysis initial analysis by CRU, final review of measurement on PC (required by ASTM)
    Uncertainty (at 20 °C) +/- (6 % of reading + 0.04) W/(m?K)
    Heating interval 300 s (typical)
    Data storage capacity 50 measurements
    Length LN02 lance 1.4 m
    Length TP09 needle 0.17m
    Diameter TP09 6.3 x 10?3 m
    Data communication USB

    WeChat

    Customer Service QQ

    Customer Hotline:

    010-52867770
    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    0l0-52867774
    l7896OO5796
    info@m.jidi9.com
    主站蜘蛛池模板: 精品国产一区二区三区在线观看| 欧美在线视频一区二区| 国产精品91久久久| 亚洲在线观看视频网站| 韩国视频理论视频久久| 国产精品久久国产精品99gif| 国产人妻互换一区二区| 国产精品吹潮在线观看| 国产啪精品视频| 久久免费福利视频| 日韩av免费看网站| 亚洲精品第一区二区三区| 国产精品欧美久久久| 韩国成人一区| 欧美中文字幕视频在线观看| 日韩一级在线免费观看| 色综合天天综合网国产成人网| 一区不卡视频| 亚洲欧美日韩在线综合| 亚洲精品免费av| 亚洲a在线观看| 亚洲 国产 欧美一区| 亚洲免费视频一区| 日韩有码在线播放| 日本一区二区三区在线视频| 日韩在线视频一区| 婷婷五月综合缴情在线视频| 亚洲不卡中文字幕无码| 天天综合中文字幕| 五月天综合婷婷| 天堂资源在线亚洲视频| 日韩国产精品一区二区三区| 日本一区高清不卡| 欧美在线视频一二三| 久久亚洲精品成人| 久久国产精品久久国产精品| 国产免费亚洲高清| 国产精品久久在线观看| 91久久精品国产91性色| 在线视频不卡一区二区三区| 日韩少妇中文字幕|