Gentec-EO QUAD-9-MT-P 4-quadrant Laser Position Sensing Detector

Updated:2025-03-13

Views:2630

Product Details

Gentec-EO QUAD-9-MT-P 4-quadrant Laser Position Sensing Detector Description:

Datasheet(CN) Datasheet(EN) User's Manual

Gentec-EO QUAD-9-MT-P 4-quadrant laser position sensing detector for CW lasers (using a chopper).

QUAD-4TRACK

The QUAD-4TRACK is a laser position sensing system designed to support our unique pyroelectric quadrant detectors, QUAD-P and QUAD-E. It is a 4-channel microprocessor-based system that measures the voltage output of each QUAD element and does the math necessary to provide a measurement of the X and Y displacement of a laser beam or image. It is fast and can be used to track, align and/or measure movement in real time, with a resolution of just a few microns!

QUAD DETECTORS

Our large area pyroelectric quadrant detectors provide unique advantages over other position sensing detectors like silicon quads or lateral effect photodiodes. They are fast, handle high peak power of pulsed lasers without saturation and respond to lasers across the spectrum, from UV to Far IR and even THz. The QUAD-E is intended for use with pulsed sources at up to 1000 Hz, while the QUAD-P is designed for CW and high repetition rate (quasi CW) sources. Both types of detectors can also be used as standalone units, in an analog mode, for incorporation into your own system application. We can provide a lemo pigtail cable for this purpose.

ANALOG OUTPUT

The analog output of the QUAD-4TRACK provides voltage that is directly proportional to the pulse energy or laser power irradiating each QUAD element. When the four voltage outputs are equal, the beam is centered on the QUAD detector. This provides a very useful tool when setting up our QUAD probes with your source for optical alignment.

MEASUREMENT SCREEN

QUAD-4TRACK includes powerful, stand alone, LabView software which is used to control the instrument, process the data, and display X and Y position. It also displays the energy or power of your source and repetition rate. The large graphic in this screen shows the position of the centroid of the beam and tracks its movement in real time. The software includes many handy features like: set boundary, zoom (2X to 128X), set resolution, data logging, and many more. The green line represents the tracking history.

TRACKING THE BEAM OVER TIME

In the measurement screen shown on the left, we are tracking the beam stability of a pulsed Nd:YLF laser at 10 Hz. The resolution was set at 0.001 nm, the boundary is at 20 μm (red circle), and the zoom feature is at 64X. The total energy is 108.5 μJ, the final position of the laser is at -8 μm in X and -8 μm in Y. The green tracking line shows the movement of the laser about the zero position over a few hundred pulses.

POSITION CALIBRATION SCREEN

We've developed a unique position calibration routine which allows you to calibrate our QUAD-4TRACK system when working with a uniformly round laser beam. It requires the use of a micrometer-driven linear stage (1-axis only). As you can see from the calibration screen on the left, the procedure involves zeroing the instrument, moving the QUAD probe to nine discrete positions (+2.000 to - 2.000 mm) and then capturing the QUAD readings. It then determines correction coefficients (last column) and applies them to the raw data to arrive at "corrected positions". The QUAD probe is now calibrated!

DATA LOGGING

Another very handy feature is "data logging". This allows you to set up the QUAD-4TRACK to follow the displacement, energy and/or power of your laser over several minutes, hours or even days. Need to measure the "beam steering" of your laser as it warms up? This is how you do it! Need to measure the beam displacement vs laser repetition rate or energy level? Data logging will help you measure it!

Key Features

Measure, Track and Align

Follow your laser beam wherever it goes.

4-Channel Detectors

Unique quadrant detector technology senses laser beam position with high resolution.

For CW, Pulsed and High Rep Rate Lasers

QUAD-E: energy per pulse from μJ to mJ

QUAD-P: powers from μW to mW

From UV to FIR and THz

Absorbers to cover all sources, from UV to millimeter wavelengths

Large Area Sensors

9 mm and 20 mm square detectors

Fast USB 2.0 Connection

Ensures full speed tracking

Includes Application Software

Complete LabView application software included, with many features

Specifications

Measurement capabilities
Noise equivalent power 1 μW
Spectral range 0.1 - 3000 μm
Typical rise time 0.02 s
Typical power sensitivity 2000 V/W
Minimum beam size 4.5 mm ?
Minimum position resolution 10 μm
Maximum chopping frequency 50 Hz
Damage thresholds
Maximum average power density 0.1 W/cm2
Maximum energy density 50 mJ/cm2
Physical characteristics
Aperture width 9 mm
Aperture height 9 mm
Absorber MT
Dimensions 63.5? X 40.6D mm
Weight 0.18 kg

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@m.jidi9.com
主站蜘蛛池模板: 国产精品综合不卡av| 国产日韩欧美综合| 久久99国产精品99久久| 国产精品色悠悠| 欧美中日韩一区二区三区| av免费精品一区二区三区| 国产亚洲欧美在线视频| 欧美欧美一区二区| 欧美一乱一性一交一视频| 日韩视频在线观看国产| 亚洲国产精品久久久久婷婷老年| 国产精品亚洲天堂| 欧美国产综合视频| 人妻av无码专区| 欧美一区二区视频在线播放| 日本精品一区| 欧美亚洲日本在线观看| 欧美亚洲日本在线观看| 欧美日韩福利在线观看| 欧美,日韩,国产在线| 久久久久久久av| 久久精品久久精品亚洲人| 久久精品视频在线| 久久riav二区三区| 久久精品91久久香蕉加勒比| 久久精品国产2020观看福利| 久久的精品视频| 国产欧美精品一区二区三区介绍| 久久亚洲免费| 精品日韩美女| 国产精品久久久久久久天堂| 国产日韩欧美中文| 国产精品美女久久久免费| 国产成人精品久久亚洲高清不卡| 国产精品777| 91精品国产亚洲| 亚洲精品中文字幕乱码三区不卡| 亚洲一区在线直播| 热久久这里只有| 蜜臀精品一区二区| 国产欧美日韩最新|