欧美国产亚洲另类动漫_在线观看不卡av_91精选在线观看_日韩精品资源二区在线

Products

current position:home page>Products>Measuring Instrument>Hukseflux>

TCOMSYS01 Hot Cube Thermal comfort measuring system

Updated:2025-03-13

Views:3031

  • Brand: Hukseflux
  • Model:TCOMSYS01
  • Description: TCOMSYS01 is a measuring system to help understand and quantify “causes and effects” leading to human thermal comfort. The TCOM01 body is temperature stabilized at 33 °C so that it offers a relatively
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

TCOMSYS01 Hot Cube Thermal comfort measuring system: User's Manual Datasheet

Introduction

TCOMSYS01 was originally designed to study the effect of radiation sources on human comfort. Equipped with heat flux sensors that measure in 5 directions and a humidity and temperature probe, it offers a good picture of energy gains and losses from all sides to a metal body that thermally resembles the human body; the TCOM01 sensor is in essence a miniature thermal mannequin.

The TCOMSYS01 system employs dedicated sensors and electronics, measuring thermal comfort according to the new Hot Cube method. The high accuracy of the MCU (Measurement and Control Unit) ensures that TCOMSYS01 will still measure down to very low heat fluxes. The MCU has a robust aluminum housing. The system generates a measurement file, including a time-stamp. The measurement data are stored in the MCU and are later downloaded to a PC. The user is responsible for data analysis.

How to employ TCOMSYS01

The primary source of information from TCOMSYS01 simply is the power [W] required to keep the TC0M01 sensor at a constant temperature; a very direct measure of human comfort. This power may be compared to the power required at 20 °C ambient air temperature, no convection (zero wind speed), and no radiation. Power consumption will immediately show if there is a situation of overheating or heat stress or a situation of overcooling or cold stress.

The second direct information supplied by the heat flux sensors of TCOMSYS01 is the heat loss or gain [W/m2] as a function of direction. If radiative sources are dominant, TCOMSYS01 will measure radiative asymmetry.

To study the exact effect of radiative sources, in many cases a simple experiment, like switching a radiation source [on] and [off] or shielding a radiation source, can be used to distinguish between convective and radiative heat transport.

Far-infrared radiation sources may be studied by temporary shielding with a silicon wafer. Silicon has around 50 % transmission. Radiation from the sun or lamps may be quantified by shading and unshading.

To study the insulating effect of clothing, TCOM01 may be insulated using the same fabrics.

A web browser may be used for real-time measurement review, data collection, and for changing control settings such as TCOM01 body temperature.

History

Already in 1929 the Eupatheoscope (from Greek “wellbeing–emotion–examination”) was designed by A.F. Dufton to quantify the condition in a room from the point of view of comfort. It consists of a blackened cylinder that is controlled to maintain a temperature of 23 °C. The power used is interpreted in terms of equivalent temperatures.

In 1990 the company Bruel & Kjear carried a thermal comfort meter (model 1212), based on the same principle, in addition to processing Fangers equation.

Both models involved only an integrated power measurement. The new Hot Cube method improves on this by incorporating omnidirectional heat flux measurements.

What makes TCOMSYS01 different?

The main contributors to thermal comfort are air temperature, airspeed, radiant temperature, and humidity. Apart from this, there are personal contributors such as metabolic rate and insulation by clothing.

Many studies use Fanger’s thermal comfort equation as applied in EN ISO 7730: Moderate Thermal Environments – Determination of the PMV and PPD indices and specification of the condition for thermal comfort. Another approach utilizes a globe temperature measurement: EN ISO 27243: Hot environments. Estimation of the heat stress on working man, based on the WBGT Index (Wet Bulb Globe Temperature).

These methods are quite indirect in particular when determining the heat flow from airspeed and radiation.

  • offers heat flux measurements. This approach is a lot more direct than the indirect estimate from airspeed and radiation.
  • TCOMSYS01 offers directional information.
  • TCOMSYS01 works at a realistic skin temperature of 33 °C (user adjustable).
  • Rated operating conditions

    TCOMSYS01 is designed to work between +10 and +25 °C. In its standard configuration, uninsulated and stabilized at 33 °C, it is rated for operation in indoor conditions including significant radiative heating.

    It will stabilize at 33 °C under approximately one of the following conditions:

  • air speeds < 5 m/s
  • irradiance < 400 W/m2
  • ambient air temperature > 5 °C
  • Under other conditions, the sensor may not be able to stabilize its body temperature due to overheating (indicating overheating or heat stress) or shortage of electrical power (indication of overcooling or cold stress). Powered using a low voltage, TCOMSYS01 is safe to use.

    TCOMSYS01 may be used for short-term outdoor experiments in the order of weeks. Under long-term exposure to solar radiation, the black heat flux sensor coating may become more reflective.

    User interface: MCU is a web server

    he MCU serves as a web server and can be connected to any local area network. No more downloading USB drivers and special interface software! Alternatively, it offers an “Ethernet over USB” or virtual Ethernet link, where you connect to the MCU using a USB cable. If you type into your web browser the MCU’s IP address (192.168.66.1 by default), you have access to the user interface.

    Ordering the TCOM01 sensor only

    The sensor TCOM01 is also available as a “sensor only”; The configuration then includes the mannequin with 5 x heat flux, 1 x temperature, 1 x heater, 2 x cable, 2 x chassis connector, and 1 x tripod. The user then must combine it with his or her own measurement and control unit.

    Suggested Use

  • surveys of human thermal comfort
  • studies of the effect of radiating sources
  • workplace investigations
  • car passenger comfort testing
  • educational purposes, illustrating heat transfer
  • bio-meteorology
  • microclimate studies
  • wind-chill analysis
  • analysis of fabric insulation
  • Areas of Application

  • Building physics / insulation, thermal comfort, and energy budget measurement
  • TCOMSYS01 Hot Cube Thermal comfort measuring system Specifications:

    Measurand heating power for stabilization, heat flux (5x), ambient air temperature, relative humidity, TCOM01 body temperature
    TCOMSYS01 specifications :
    TCOM01 temperature setting 33 °C (user adjustable)
    Included cable 2 x cable with 2 connectors (1.5 m)
    Standard rated operating temperature range +10 to +25 °C
    Limiting temperature range – 25 to +50 °C
    Required data analysis To be performed by the user
    Data display in web browser
    Start up interval < 10 min
    TCOM01 specifications :
    Weight 1.12 kg
    Temperature sensor 10 kΩ thermistor
    IP protection class IP65
    Mounting tripod with ? inch -20 UNC screw; a Manfrotto Pixi EVO 2-section tripod is included
    MCU specifications :
    User interface on MCU as a web page
    Connection via LAN or “Ethernet over USB”
    Voltage measurement accuracy 4 x 10-6 V (0.8 W/m2)
    Rated power supply voltage 10 to 16 VDC
    Adapter power supply 100 – 240 VAC, 50/60 Hz
    Rated operating temperature range MCU – 25 to +50 °C
    Data storage capacity 2GB; > 1 year of data
    Options 2GB; > TCOM01 sensor only extended rated operating conditions; temperature, irradiance, wind speed

    WeChat

    Customer Service QQ

    Customer Hotline:

    010-52867770
    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    0l0-52867774
    l7896OO5796
    info@m.jidi9.com
    主站蜘蛛池模板: 久久精品视频亚洲| 欧美激情久久久久| 中文字幕久久综合| 极品尤物一区二区三区| 国产精品久久久久久久久久久久午夜片| 亚洲伊人久久大香线蕉av| 国产精品99久久久久久人| 久久久久久久久91| 亚洲精品第一区二区三区| 日本亚洲欧美三级| 国产精品91久久久| 国产又爽又黄的激情精品视频| 久久久国产影院| 欧美精品久久久久a| 国产精品亚洲精品| 久久久精品在线观看| 日韩欧美一区二区在线观看| 亚洲一区二区三区在线免费观看| 国产99在线免费| 国产精品国产亚洲伊人久久| 国产欧美日韩视频| 国产欧美日韩最新| 久久久久99精品成人片| 久久中文精品视频| 日本丰满少妇黄大片在线观看| 日韩精品一区二区三区外面| 日韩一区二区高清视频| 日韩色av导航| 日本不卡视频在线播放| 日韩暖暖在线视频| 日本中文不卡| 欧美日本国产在线| 久久久久久久久亚洲| 99免费在线视频观看| 日韩在线精品视频| 激情深爱综合网| 国产欧亚日韩视频| 国产精品亚洲二区在线观看| 久久久久99精品久久久久| 日韩亚洲欧美中文在线| 久久久久福利视频|